Download Option

Transcript
(V: vertical, H: horizontal)
z Color Free Xros M available
z Up to 3 lines
z Acoustic output power: 7%-100%
z Gain: 0-100, 1-2/step
z Speed: 1-6, 6 steps
z Tint map: off; 16 types
z Gray Map: 8 types
4.6 Free Xros CM (option)
z Display formats: V2:3, V3:2, V3:1, H2:3,
(V: vertical, H: horizontal)
z Acoustic output power: 7%-100%
z Gain: 0-100, 1-2/step
z Speed: 1-6, 6 steps
z Tint map: off; 16 types
z Gray Map: 8 types
4.7 Color Doppler Imaging
z Dual live
TM
z iTouch : Auto optimization (Gain)
z Frequency (depend on probe)
z Max. velocity: 199.9cm/s
z Steer: max. 20° (linear transducer)
z Max. frame rate: 268f/s
z Acoustic output power: 7%-100%
z Gain: 0-100, 2/step
z ROI size/position: adjustable
z Scale: 30 steps (depend on exam mode)
z Baseline: -8~+8, 17 steps
z Wall filter: 0-7, 8 steps
z PRF: max. 7.8kHz
z Packet size: 0-3, 4 steps
z Velocity tag: on/off
z Smooth: 0-4, 5 steps
z B/C Align: on/off
z Priority: 0%-100%, 10%/step
z Map: V0-V10, VV0-VV9, 21 types
z Invert: on/off
z Persistence: 0-4, 5 steps
z Line density: L/M/H/UH, 4 steps
4.8 Power Doppler Imaging
z Dual live
z Support directional PDI
z Frequency (depend on probe)
z Acoustic output power: 7%-100%
z Dynamic range: 10-70, 5/step
z Gain: 0-100, 2/step
ROI size/position: adjustable
z Steer: max. 20° (linear transducers)
z Scale: 30 steps (depend on exam mode)
z Wall filter: 0-7, 8 steps
z PRF: Max. 7.8kHz
z Packet size: 0-3, 4 steps
z Smooth: 0-4, 5 steps
z B/C Align: on/off
z Priority: 0%-100%, 10%/step
z Map: P0-P3, dP0-dP3, 8 types
z Persistence: 0-4, 5 steps
z Line density: L/M/H/UH, 4 steps
4.9 PW/CW-Mode
z Display formats: V2:3, V3:2, V3:1, H2:3,
Full (V: vertical, H: horizontal)
TM
z iTouch : Auto optimization (Baseline,
PRF)
z Frequency (depend on probe)
z PW velocity: max. 924.0cm/s
z CW velocity: max. 6160cm/s
z Sample volume size: 0.5-20mm (PW
only), 0.5-5mm/step
z Sample gate depth: adjustable
z Scale: 30 steps
z Baseline: -4~4, 9 steps
z PW Steer: max. 20° (linear transducer)
z Audio: 0%-100%, 2%/step
z PW PRF: max. 24kHz
z Gain: 0-100, 2/step
z Dynamic range: 24-72, 2/step
z Speed: 1-6, 6 steps
z Wall filter: 0-6, 7 steps
z Invert: on/off
z Angle: -89°~89°, 1/step
z Quick angle: 0°, -60°, 60°
z Gray map: 8 types
z Tint map: Off; 16 types
z Time/frequency resolution: 0-4, 5 steps
z Auto calc: on/off
z Trace area: above, below, all
z HPRF: on/off
4.10 Tissue Velocity/Energy Imaging
(included in TDI option)
z Available on phased array transducer
z Dual live: side by side displays B and
B+TVI
z
5