Download Minipack, PS System
Transcript
Customer connections L1 N L2 N L3 N PE PE 8 7 6 5 4 3 2 1 X5* * To be labeled Mains input terminals + - + - + - L N PE + - Power module 4 L N PE Power module 3 L N PE Power module 2 L N PE Power module 1 2 JP2 CAN1 Smartpack Power -/CAN bus Interconnections pin 1-8 X Con5A* 3 Smartpack Connection Optional Y K1 LVLD Y2 Power input - 1 Power output – Y8 3 Y1 Power input + 2 Power output + Y7 JP1 NEG. DIST. 1 POS. DIST. Y9 Y18 Y12 TB1 To Dist board 2 Y2 high pri load Y1 Y4 Y3 Y25 Y24 Y7 Y6 1 F10 SERIAL S1 DIFF Load circuits -48Vdc + + + + + + + - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 *Con 7 Temp sense Battery Fuse Fail 2 Battery Current 2 Temperature Sense 2 Batt. Symmetry 8 Batt. Symmetry 7 Batt. Symmetry 6 Batt. Symmetry 5 *X3 Battery Connections Battery Connections 200576 2 F9 3 F8 5 6 7 8 9 DC output 10 4 2 F7 F6 F5 F4 F3 F2 F1 X6B* DC Earth (TE) Con 3A* Battery Connections Y3 Fuse alarm Y4 Y5 Y5 low pri load Y6 15 Customer connections 215792 Dist.Board 2 MPBB 100A 10pos G1 0V Y7 System connections Batt. Fuse Fail + 1 Batt. Fuse Fail - 2 3 LVD 1A 4 LVD Common SH1 To battery contactor X7A* To battery + Y19 Y20 1 2 3 4 5 6 7 8 9 10 DC output + 217915 Dist board 1 Minipack System MCB 10 pos load 4 pos batt X6A* Customer connections 15 Y X LVBD See Std. Documentation 356804.10x 213333 Underwiring MPBB 6pos 3AC 15 SERIAL S1 DIFF Con 4A* Battery Connections 1 2 3 4 5 6 7 8 9 10 11 12 13 14 8 Sym. 2 *Con 6 Temp sense Not Connected Not Connected Temperature Sense 1 Batt. Symmetry 4 Batt. Symmetry 3 Batt. Symmetry 2 Batt. Symmetry 1 + + + + + + + - *X4 Battery Connections Battery Connections 200576 NA for Smartpack RS232 rear Alteration CR 070103NA 15 NA for Smartpack Web/SNMP 8 8 10 8/26 9/15 15 15 2007-01-03 SHWINO Date/Sign See Std. Documentation 356804.10x POS. DIST. NEG. DIST. 15 + + + Digital Input 5 + Digital Input 6 NO COM 2A* 1 2 3 4 5 6 7 8 9 10 NO COM NC NC NO COM NC NO COM NC 11 12 13 14 15 16 17 18 19 20 USB Consultant ORSKNO ORSKNO Draw FRNONO Approved Scale 9 - A3 Format Page 1 of 1 2023227 Draw. No. - Replace for 2 Rev. Replaced by Copyright A/S Eltek. All rights reserved Eltek Customer connections Battery Strings Circuits -48Vdc Projection Block Diagram Minipack 48Vdc 3,2kW Design 07 Dec. 2006 Optional Web/SNMP (ENET) connection. Replaces ”Ext. Alarm I/O Connections” 2: Date Optional 9 pin D-sub RS232 connection. Can be mounted in front or on rear side of Smartpack. Replaces ”Ext. Battery Connections” when mounted on the rear side of Smartpack 1: Optional: RS232 USB 2.0 type B port (PC connection) Front connections Relay 6 Relay 5 Relay 4 Relay 3 X2B* Ext. Alarm I/O Connections Con Ext. Alarm I/O Connections Digital Input 4 Digital Input 3 1: CAN port CAN port CON1 Alarm I/O Connections 1 2 3 4 5 6 7 8 9 10 X2A* Ext. Alarm I/O Connections CON3 Ext. Battery connections 1: Optional: RS 232 CON2 Ext. Alarm I/O Connections 2: Optional: Web/SNMP (ENET) CON4 Battery connections Relay 2 Relay 1 + + NO COM NC NO COM NC Alarm Outputs and Digital Inputs 218473 Con 1A* Alarm I/O Connections Smartpack monitoring and control unit 26 CON5 System Connections Rear connections 10 Digital Input 2 Digital Input 1 X1* Alarm I/O Connections Alarm Outputs and Digital Inputs 218470 - FBn - FB1 Customer connections