Download Pledco broadcast user`s manual

Transcript
8. Trouble shooting
This chapter introduces some possible trouble symptoms and their remedial treatment to the Broadcast
display.
TIPS:If a problem is seen on an LED display and its cause is hard to diagnose, please write down a
description of the symptom as detailed as possible, take some pictures and report to the
Manufacturer for help.
CAUTION:Before any operation on the PCB or any wire connection is carried out, all power
supplies to the LED display MUST be co mpletely disconnected. When doing wire
connection, please make sure all wires have been connected properly and securely.
Symptom
Cause Analysis
Remedy
One tile is not displaying or is
not displaying properly.
ƒCables connected to the tile get
loose.
ƒConnect the cables properly.
ƒThe signal cable inside the ƒChange the connectors on the
power box of the tile hasn抰 been
tile and those inside the power
properly connected.
box, if necessary.
ƒSomething is wrong with the tile
ƒReplace the tile.
itself.
A small segment of the tile is
not displaying the right color,
or the segment is
uncontrollable.
ƒSomething is wrong with the tile
itself.
One unit cannot display
properly.
ƒFirmware or data on the Unit
controller get lost.
ƒTile controller is broken.
A unit keeps displaying the
address number.
ƒSignal cables between Units are
not connected well.
ƒFirmware on the Unit controller
is impaired.
ƒUnit controller is broken.
ƒThe gamma data on the Unit
controller
have
been
set
One unit shows a different
differently from those on other
color or brightness from other
Unit controllers.
units.
ƒThe brightness data on the Unit
controller are different from
those on other Unit controllers.
A whole patch above a
certain unit in a master block
goes completely dark.
One block cannot light on.
ƒUpdate the CPU program or
data on the Unit controller.
ƒReplace the Unit controller.
ƒConnect
the signal cables
between Units properly and
securely.
ƒUpdate the CPU program or
data on the Unit.
ƒReplace the Unit controller.
ƒCheck the gamma data of the
Unit in Broadcast Tools and set
them same as those on other
controllers.
ƒUpdate the brightness data on
the Unit controller or set them to
be same as those on other
controllers.
ƒEither the power supply or the
cable connection of the failed
Unit at the lowest position needs ƒCheck the power supply and the
to be fixed.
power cable of the Unit. Replace
ƒThe signal cable connecting to
them if necessary.
the failed Unit at the lowest ƒCheck the cable connection on
position hasn't been properly
the Unit controller. Connect them
connected.
properly.
ƒThe control board of the failed
ƒReplace the Unit controller.
Unit at the lowest position may
be impaired.
ƒCheck the power cable and
ƒThere is no power into this
power connector of the Block.
Block.
ƒCheck the connectors at both
ƒThere is no signal into this Block.
ends of the signal cables of the
59 / 66
www.pledco.com
ƒReplace the tile.