Download X64-LVDS User`s Manual
Transcript
Camera Trigger Method #2 Camera Trigger Method #2 This method generates an asynchronous trigger pulse to a camera. The next generated frame will be acquired. The trigger pulse using this method controls the number of lines output by the camera and is usually used to control the length of the frame output by the camera. The trigger duration specifies the minimum time in between 2 triggers for the camera to operate properly. Example Video Progressive Trigger Pulse duration Frame Acquired Refer to CORACQ_VAL_CAM_TRIGGER_METHOD_2 in the Sapera Acquisition Parameters Reference Manual (OC-SAPM-APR00). Line Integration Method #1 Line Integration Method #1 This method generates 2 pulses. The distance between the end of the first pulse(#0) and the start of the second pulse (#1) is the integration time. The 2nd pulse is also the Line Trigger input to the camera. For example, on a Dalsa camera, the 1st pulse would be the 'Prin' signal while the 2nd pulse would be the 'Exesync' signal. Example Integration Pulse #0 pulse #0 width Integration Pulse #1 exposure time pulse #1 width Line Valid Refer to CORACQ_VAL_LINE_INTEGRATE_METHOD_1 in the Sapera Acquisition Parameters Reference Manual (OC-SAPM-APR00). 56 • X64-LVDS Reference X64-LVDS User's Manual