Download 3.6 Status - Milesight
Transcript
User Manual 3.5.4 Alarm Output Alarm Output function is supported on MS-N5016, MS-N5116, MS-N8016, MS-N8032. Step 1: Select Main Menu-Event-Alarm Output: F-3.5.22 Step 2: Set Alarm output channel, Alarm Name, Alarm Type and Record Channels: [Alarm Output NO]: The channel which will output the alarm signal; [Alarm Name]: Set a name for the alarm; [Alarm Type]: Select alarm type: NO or NC; [Dwell Time]: Set the output time for alarm, if that is too long when alarm out is outputting, you can select the Manually Clear to stop it. Step3: Select Effective Time for alarm output: www.milesight.com 59