6.Connection to Computer
(3) Setting data format
Set the same data format to this device and the computer. The DIP switches are set as shown in the
table below by default. Before changing the settings of the DIP switches, be sure to turn the power of
the device off. When setting the data format of the computer, refer to its operation manual.
OFF
ON
1
2
3
4
5
6
#1 DIP switch function: Set the device as follows:
(* refers to the default settings)
DIP
SW No.
Meaning
ON
OFF
1
Sets Communication data
Data bit length = 8
format.
Data bit length = 7 *
2
Sets Communication data Parity check disabled
format.
*
Parity check enabled
3
Sets Communication data
Odd parity
format.
Even parity
4
Sets Communication data
Stop bit length = 1
format.
Stop bit length = 2 *
5
Read timing
Mark-to-mark type
Direct-under type
Changes line compatible
code in E mode
0123 ∼ : ; < = >
987∼XYABC
Lines to read
6
Card used in test mode
7,8
(note)
15
*
*
12
Postcard-sized, timing Card-sized, timing
control type
direct-under type
Operation mode
7
8
SR-430 *
(SR-410 compatible)
OFF
OFF
SR-307 compatible
ON
OFF
SR-305 compatible
SR-305S compatible
OFF
ON
Not used
ON
ON
*
Note:
Note that the reading sensitivity is graded in eight levels in the compatible mode.
-23-
7
8