Download SVmco - Fujitsu
Transcript
SVmco User Guide The numbers shown under ioc are slot numbers. To stop the rotation of an HDD to be replaced or removed o # /opt/fujitsu/SVmco/bin/diskctrl -e ioc0/3 To confirm the mounting location for an HDD to be added o # /opt/fujitsu/SVmco/bin/diskctrl -i ioc0/3 o To turn off the blinking FaultLED indicating the location of the HDD that must be replaced or inserted # /opt/fujitsu/SVmco/bin/diskctrl -o ioc0/3 To turn off the Fault LED after stopping disk rotation o # /opt/fujitsu/SVmco/bin/diskctrl -c ioc0/3 In Windows The following example shows all the SGPIO controllers in the operating system and a list of their slot statuses. diskctrl -l SGPIO controller and slot status (Windows) Display example Description of status 91