Download Tektronix scope programmer`s manual
Transcript
Waveform commands also work with extended-acquisition-length mode. This mode lets the oscilloscope acquire extended acquisition lengths of 2M, 4M, and 8M while maintaining waveform record lengths limited to 500K. In other words, the acquisition data for a channel may be bigger than a waveform you view. Then, after the data is acquired, you can move to and display any portion of the data. This mode lets you select a subsection of the larger acquisition data. You can select the starting and ending positions in the acquisition data and the waveform record. NOTE: To function properly, extended acquisition mode forces some oscilloscope modes and settings to new values. Also, measurements, gating, and cursors are restricted to the current waveform record. Table 2-24 below shows the correlation between the number of channels in use and the waveform record lengths. Table 2-24: Table of Extended-Acquisition-Length Mode Channels and Record Lengths ============================================= Waveform # of Channels in Use Extended Record Length Acquisition Length ------------------------------------------------------------------------------8 M samples 500 K samples 1 of 4 (not on the TDS 520D and TDS 724D) ------------------------------------------------------------------------------2 of 4 4 M samples 250 K samples (or on the TDS 520D and TDS 724D: 1 of 2) ------------------------------------------------------------------------------3 or 4 of 4 2 M samples 100 K samples (or on the TDS 520D and TDS 724D: 2 of 2) From a software development viewpoint, to define how much of the extended acquisition length data to include, you can use the DATa:STARt and DATa:STOP commands. To define the waveform record within the extended acquisition data, you can use the HORizontal:RECORDSTART or HORizontal:POSition command. The CURVe? query will return the extended acquisition data as you defined it with DATa:STARt and DATa:STOP. With extended-acquisition-mode set to on, this can be much larger than the waveform record. With extended-acquisition-mode set to off, this is equal to the waveform record. Commands related to extended-acquisition-length mode operations include: CURVe, DATa RECORDSHAp, DATa SOUrce, DATa:STARt, DATa:STOP, HORizontal:ACQDURATION?, HORizontal:ACQLENGTH, HORizontal:EXTDACQ, HORizontal:POSition, HORizontal:RECORDSTART, RECAll:ACQDATA, SAVe:ACQDATA, and WFMPre:<wfm?>. NOTE: Extended-acquisition-length mode CURVe? queries can easily return more data than will fit on a 1.44 Mbyte floppy. For example, to return an entire 8 M extended acquisition mode record 63
Related documents
PCM DECODING PCM DECODING
Programmer Manual TDS200, TDS1000/TDS2000
Programmer Manual
TEK TDS 500D,TDS600C, TDS700D Series & TDS714L Technical
Link to 500, 600, 700 Specifications/User Manual
Canon BJC80 - BJC 80 Color Inkjet Printer Specifications
Tektronix TDS8000 Digital Sampling Oscilloscope
Programmer Manual TDS 340A, TDS 360 & TDS 380 Digital Real
Tektronix TDS 500B User's Manual
Artisan Technology Group is your source for quality new and
TDS200, TDS1000, TDS2000, and TPS2000 Series Digital
Tektronix TDS500C User's Manual