the deceleration time.
According to servo driver and the load, etc., deceleration time can be used flexibly.
Rotating
speed
Time
Forward order
[FWD]
ON
OFF
OFF
Parameter 35
Parameter
s 36
When the upper control device output analog speed voltage, and the servo amplifier's
frequency dividing output use position control in feedback way, please set the acceleration
time and deceleration time in 0.000 seconds.
Pn-39
No.
Name
Zero
39
Set
range
Initial value
speed
clamp electrical 0.0~500.0[r/min](0.1Scale)
1.0
level
Change
All the
time
※valid in position control and speed control
Set the servo motor rotation speed of zero speed clamp.
Valid in the input position control and analog speed command of speed control.
If the speed command value of analog speed command (Vref) input terminal is below zero