Heat pump operation – User level v. 1.04
Using the dial knob and the confirmation button you can select and open the following options
to set the effect of the tariffs on the heat pump operation:
DHW tariff
stop
DHW tariff
start
HeW tariff
stop
HeW tariff
start
Pool tariff
stop
Pool tariff
start
Return
-
-
Disables the effect of high tariff for electricity on heating
the domestic hot water.
Enables the effect of high tariff for electricity on heating
the domestic hot water.
Disables the effect of high tariff for electricity on heating the heating
water
Enables the effect of high tariff for electricity on heating the heating
water
Disables the effect of high tariff for electricity on heating the pool.
-
Enables the effect of high tariff for electricity on heating the pool.
-
Exits setting the effect of the tariff on the heat pump operation.
-
Disabling the Effect of the Tariff on Heating the DHW by HP
This menu allows to set the outdoor temperature limit below which the heat pump heats the domestic
hot water regardless of the high tariff for electricity. If the ambient temperature is higher than the set
limit, the DHW is heated only at the low tariff. If the ambient temperature drops below the set limit,
the DHW is heated as necessary, regardless of the current tariff. When the ambient temperature
increases, effect of the tariff is enabled only when the outside temperature exceeds the limit that
enables the effect of the tariff (see the next chapter). The temperature limit that enables the effect of
the tariff must be set about 2C higher than the temperature limit that disables the effect of the tariff
(hysteresis). To permanently disable the effect of the tariff, you must set both the enabling and
disabling temperature limits for heating DHW according to the tariff to the maximum possible value, i.e.
to +30C.
Ambient temp.
Tarif start
hysteresis
Tarif stop
Time
Fig. 5. Diagram of the disabling/enabling the effect of the tariff
When the status line is displayed, press the confirmation button to enter the main menu and use
the procedure described in chapter 7.1.3. on page 34 to open the Tariff settings menu. After opening
this menu, its first option is displayed.
Tariff settings
DHW tariff stop
After opening this menu, display shows
DHW tariff stop
xx.x
- 35 -