Download VHD Preamp User Guide
Transcript
100 - 240 VAC, 50/60 Hz MAX 30WATTS WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENTS. NO OPERATOR SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. Our aim is to create audio products that absorb you, place you within the performance and deliver a listening experience beyond expectation. A/B CONTROL RIGHT LEFT KV2 AUDIO, MANUFACTURED IN THE EUROPEAN UNION, OUTPUT B At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source. SERIAL NUMBER OUTPUT A WWW.KV2AUDIO.COM RIGHT LEFT The future of sound. Made perfectly clear. AC IN LEFT RIGHT UNBAL. INPUT RIGHT BAL. INPUT LEFT MIC. INPUT 48V CLIP -20dB TECHNOLOGY ON 0 BASS 0 +15 dB TREBLE 0 +12 dB -15 dB HIGH MID 0 +12 dB -12 dB LOW MID 0 +15 dB -12 dB MICROPHONE 500 Hz -15 dB HIGH PASS 100 Hz +55 dB 10 Hz GAIN +6 dB 00 VOLUME -20 dB 0 dB BAL CLIP UNBAL -10dB INPUT +6 dB GAIN +30 dB -6 dB LINE BASS 0 dB +6 dB -6 dB +6 dB TREBLE 0 dB 00 VOLUME -20 dB 0 OUTPUT A B VERY HIGH DEFINITION PREAMP SELECT POWER VHD Preamp User Guide VHD Preamp Safety Instructions IMPORTANT SAFETY INSTRUCTIONS Observe all instructions and follow warnings marked on the equipment and in the user’s manual. Connect the equipment only to a source of proper mains voltage. Do not attempt to switch on any equipment that has been dropped, that is damaged, or has had liquid penetration, or if malfunctions have occurred and their nature requires a repair action. The supply cable shall be made by a person having proper qualifications. WARNING The equipment is designed in Class I and shall be connected to a wall socket having protective earthing. The mains plug and supply cable shall remain easy accessible, as this is used for disconnection of the equipment from the supply source if necessary. Never interrupt earthing due to safety reasons. Do not place the equipment close to heating bodies or other sources of heat and protect it against direct sunlight. The equipment must not come into contact with open flames. Ventilation of the equipment must not be obstructed by covering of ventilation openings. The equipment must not be exposed to dripping or splashing liquid or water and excessive humidity. Any object filled with any liquid shall not be placed on the equipment. The triangle with a symbol of a lightning marks parts of the equipment under life jeopardizing voltage, whose values may cause an injury from electric shock. Safety Instructions The symbol indicating that the equipment is manufactured in compliance with EU standards. 2 The triangle with a symbol of an exclamation mark in the text marks important instructions for operation, setting and maintenance. Basic Description The VHD Preamplifier is a Very high definition, small stand-alone microphone and stereo inputs signal mixer. Primarily built for high quality, easy presentation and comparisons of two individual systems using the same source, the applications for this mixer are comprehensive and extremely useful. The VHD Preamp features a stereo pair of balanced line inputs, stereo RCA phono connectors, and a very high quality VHD microphone preamplifier. The microphone channel features phantom power, four band equalization and a variable high pass filter. The VHD Preamplifier also features two switchable A or B outputs, to allow a simple comparison of systems between the two outputs. Both A and B outputs have line drivers built into them to maintain audio signal integrity over long cable lengths. VHD Preamp Description Front panel Microphone preamplifier HIGH PASS 100 Hz GAIN +6 dB TECHNOLOGY BASS 0 LOW MID 0 Stereo preamplifier HIGH MID 0 TREBLE 0 VOLUME -20 dB GAIN BASS 0 dB INPUT BAL TREBLE 0 dB VERY HIGH DEFINITION PREAMP VOLUME -20 dB POWER UNBAL 48V -20dB ON CLIP CLIP 0 +55 dB 10 Hz 500 Hz -15 dB +15 dB -12 dB +12 dB -12 dB +12 dB -15 dB +15 dB 00 SELECT -10dB 0 dB A +6 dB MICROPHONE +30 dB -6 dB +6 dB -6 dB +6 dB 00 B 0 LINE OUTPUT Rear panel AC IN SERIAL NUMBER A/B CONTROL RIGHT OUTPUT B LEFT RIGHT OUTPUT A LEFT UNBAL. INPUT RIGHT BAL. INPUT LEFT MIC. INPUT RIGHT 100 - 240 VAC, 50/60 Hz MAX 30WATTS WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENTS. NO OPERATOR SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. LEFT KV2 AUDIO, MANUFACTURED IN THE EUROPEAN UNION, WWW.KV2AUDIO.COM Block diagram PREAMPLIFIER CLIP HIGH PASS FITER EQUALIZATION LINE DRIVER BASS RIGHT LMID HMID TREBLE UNBALANCED INPUT PREAMPLIFIER HIMID TREBLE BASS LOWMID HIGH PASS -20 dB GAIN VOLUME 48 V STANDBY MUTE OUTPUT A Description MIC. INPUT EQUALIZATION RIGHT LINE DRIVER LEFT LINE DRIVER RIGHT CLIP LEFT BAL. INPUT RIGHT MIXER STANDBY MUTE VOLUME INPUT LMID HMID TREBLE TREBLE BAL. INPUT LEFT GAIN -10 dB BASS BASS OUTPUT B OUT. SEL. DRIVER A/B SELECT OUTPUT SELECT LINE DRIVER LEFT 3 Using the system Demonstration / presentation mixer VHD Preamp Two sound systems comparing System B System A System B System A VHD Preamp Rear view AC IN A/B CONTROL SERIAL NUMBER RIGHT OUTPUT B LEFT RIGHT OUTPUT A LEFT UNBAL. INPUT RIGHT BAL. INPUT LEFT MIC. INPUT Using the system RIGHT 100 - 240 VAC, 50/60 Hz MAX 30WATTS WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENTS. NO OPERATOR SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. LEFT KV2 AUDIO, MANUFACTURED IN THE EUROPEAN UNION, WWW.KV2AUDIO.COM Stereo player Unbalanced Input Balanced Input Narrator's microphone 4 Using the system Simple AV mixer-Projector sound and a microphone VHD Preamp Sound system Sound system Input VHD Preamp Rear view AC IN SERIAL NUMBER A/B CONTROL RIGHT OUTPUT B LEFT RIGHT OUTPUT A LEFT UNBAL. INPUT RIGHT BAL. INPUT LEFT MIC. INPUT RIGHT WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENTS. NO OPERATOR SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. LEFT KV2 AUDIO, MANUFACTURED IN THE EUROPEAN UNION, WWW.KV2AUDIO.COM Stereo player Narrator's microphone Using the system 100 - 240 VAC, 50/60 Hz MAX 30WATTS 5 Using the system Replacement FOH mixer VHD Preamp Replacement mixer for FOH when the main system is being taken down after a concert. Many venues now insist that at least one pair of speakers and a mixer/mic is kept available during breakdown. Main system - PA (A) Main system - PA (A) Replacement PA (B) Replacement PA (B) Replacement system In Main system In VHD Preamp Rear view AC IN SERIAL NUMBER A/B CONTROL RIGHT OUTPUT B LEFT RIGHT OUTPUT A LEFT UNBAL. INPUT RIGHT BAL. INPUT LEFT MIC. INPUT RIGHT Using the system 100 - 240 VAC, 50/60 Hz MAX 30WATTS WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENTS. NO OPERATOR SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. LEFT KV2 AUDIO, MANUFACTURED IN THE EUROPEAN UNION, WWW.KV2AUDIO.COM Stereo player Narrator's microphone 6 Specifications System Acoustic Perfomance -3dB Response Total Harmonic Distortion 10Hz ÷ 50kHz <0.0005% Output Channels Number of Channels Max. Output Voltage Max. Output Current 2 14V / 7V (50Ω) RMS 450mA Signal Input Input Channels Input Impedance Mic input Line input 5 2kΩ Mic / 20kΩ Balanced IN / 10kΩ RCA Phantom power, -20dB, Input level RCA/Balanced, 2 band EQ, -10dB Signal Output Output channels Output Impedance Features High Pass Filter Equalization stereo A / stereo B 50Ω IEC 320 100÷250V@50÷60Hz Physical Dimensions Height Width Depth Weight 44.5mm (1.75") 483mm (19.0") 177.8mm (7.0") 2.5kg (5.5lbs) Input / Output connectors wiring XLR Balanced Input and Output connectors 2 1 3 Output 1 2 3 1 = Ground 2 = Hot (+) 3 = Cold (-) Specifications 10Hz ÷ 500Hz 4-band EQ Power Power Connector Operating Voltage Range Input VHD Preamp VHD Preamp - SPECIFICATIONS 7 The future of sound. Made perfectly clear. At KV2 Audio our vision is to constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source. Our aim is to create audio products that absorb you, place you within the performance and deliver a listening experience beyond expectation. KV2 Audio, Nádražní 936, 399 01 Milevsko, Czech Republic T +44(0)1423 816868 F +44(0)1423 816869 www.kv2audio.com KVV120031-00-01-0