Download PustN0507 - ScholarWorks
Transcript
217 The Filter Settings GUI controls many of the instruments functions. By using the toggles at the top, the lens for which the settings are being adjusted can be selected. When the buttons are used to toggle different lenses, the new lens settings are updated and available for change. The description boxes describe the filters in the instrument. These should only be changed if the filters are changed. The filter descriptions are the same for all lenses. (These are the only settings displayed that apply to all lenses.) The Active column determines which filters are acquired. In the example shown, only the 530 nm and 700 nm filters are active for the fisheye lens. Therefore, if Take Image Sequence is selected, first the 530 nm data will be acquired; then, the 700 nm filter will be acquired. If other filters were active, then each filter would be acquired sequentially in order of position in the filter wheel after the Take Image Sequence button is selected. The focus positions are unique for each filter and each lens. These position settings are set prior to calibration and should not be adjusted after calibration, because of the focus dependence of the calibration. To help with the initial adjustments, the current focus setting is shown in the GUI. The exposures can be adjusted between 6 and 250 msec. To make adjustments to all wavelengths simple, a ±20% adjustment toggle is at the top of the column. These toggles adjust the exposures of all wavelengths simultaneously. To disable processing of the polarization parameter online—that is to only save the raw data, go to the Data Processing drop down menu. If Process Online is checked, then click on it. (Processing the data at the time of acquisition is the default setting.) After these settings are properly adjusted, data collection can start by pressing Take Image Sequence. If it is desired to automatically continue taking data, the Loop button can be depressed. This button causes the imager to continue to run the Take Image Sequence until the user intervenes. The default delay between acquisitions is 0 seconds. The loop delay time is set in the Options GUI, discussed later. Displaying Data The primary default display is shown in Figure 9.1. By using the R, S, and P toggles (or their linked settings in the View drop down menu), different views can be achieved. R stands for Raw images, S for Stokes parameters, and P for Polarization parameters. By toggling these different items off, fewer images are displayed on the main GUI and can be viewed with higher resolution. For example, if one the P is toggled, the Polarization parameters of DoLP, DoCP, AoP, and DoP are displayed in a 4 x 4 image inside the mainframe. When all three categories are toggled off, the software reduces the Polarization GUI to the toolbar only. This view is useful during data acquisition to simultaneously view the MATLAB command window and status bar of the Polarization GUI. Figure 9.5 shows an example of this setup.