Download PustN0507 - ScholarWorks
Transcript
75 a horizontal (0°) slice across the center of the fisheye image. To calibrate the whole image, the polarimeter itself was rotated -45º, 0º, 45º,and 90º, while the luminance standard and polarizer were left in place to obtain slices that covered the whole image area. Figure 4.7. Setup used in the fisheye lens calibration. The luminance standard and the polarizer rotate together in the direction of the arrow for each calibration piece. One problem with the fisheye calibration is the issue of reference plane. The fisheye itself rotates the polarization vector. As an example, consider a fisheye lens viewing the sky dome with the horizon at 90º from the optical axis (because the imager is looking up). The orientation of the polarizer sets the zero–azimuth angle. Horizontal polarization is defined as parallel to the horizon. Light incident from the horizon at 0º azimuth with a vertical polarization vector will be measured to have an angle of polarization of 0º by the polarimeter; however, light incident from the horizon at 90º of azimuth with horizontal polarization also will be measured to have an angle of