Transcript
MONITOR PROGRAM CHAPTER 3 MONITOR PROGRAM 3.1 INTRODUCTION This chapter is a description of the monitor program. This description enables you to understand the basic structure of the program. 3.2 PROGRAM DESCRIPTION The BUFFALO (bit user fast friendly aid to logical operations) monitor program is supplied with the EVBU. The EVBU monitor program is stored in the MCU internal ROM and communicates via the MCU serial communications interface (SCI). Refer to the buf32.asm file on the EVBU diskettes for additional information pertaining to the monitor (BUFFALO) program. The BUFFALO monitor program consists of five parts (or sections) as follows: 1. Initialization 2. Command interpreter 3. I/O routines 4. Utility subroutines 5. Command table 3.2.1 Initialization This part of BUFFALO contains all of the reset initialization code. In this section, internal RAM locations are set up, and the I/O channel for the terminal is set up. To set up the terminal I/O port, BUFFALO must determine if the terminal is connected to the SCI (as in the EVBU) or to an external ACIA or DUART. This is accomplished by sending a sign-on message to all ports and then waiting for you to type carriage return <CR> on whichever device is the terminal port. When BUFFALO recognizes a carriage return from a port, that port is then used for all subsequent terminal I/O operations. The EVBU terminal device is normally connected to the SCI. M68HC11EVBU/D 3-1 1