Download MICROMASTER 430

Transcript
Parameters
P2014[2]
Issue 03/02
USS telegram off time
CStat:
CT
P-Group: COMM
Datatype: U16
Active: Immediately
Unit: ms
QuickComm. No
Min:
Def:
Max:
0
0
65535
Level:
3
Defines a time T_off after which a fault will be generated (F0070) if no telegram is received via the USS
channels.
Index:
P2014[0] : Serial interface COM link
P2014[1] : Serial interface BOP link
Notice:
By default (time set to 0), no fault is generated (i.e. watchdog disabled).
r2015[8]
CO: PZD from BOP link (USS)
Datatype: U16
Min:
Def:
Max:
Unit: -
P-Group: COMM
Level:
-
3
Displays process data received via USS on BOP link (RS232 USS).
r2015[0]
r2015[1]
r2015[2]
r2015[3]
PZD1
STW1
PZD2
HSW
PZD3
.
.
.
PZD4
STW2
r2032
r2033
r2015[7]
P2012
STX
LGE
ADR
PKW
Parameter
PZD
Process data
USS telegram
USS on BOP link
BCC
STX
LGE
ADR
PKW
PZD
BCC
STW
HSW
Start of text
Length
Address
Parameter ID value
Process data
Block check character
Control word
Main setpoint
PZD mapping to parameter r2015
Index:
r2015[0]
r2015[1]
r2015[2]
r2015[3]
r2015[4]
r2015[5]
r2015[6]
r2015[7]
:
:
:
:
:
:
:
:
Received word 0
Received word 1
Received word 2
Received word 3
Received word 4
Received word 5
Received word 6
Received word 7
Note:
The control words can be viewed as bit parameters r2032 and r2033.
Parameter List
108
MICROMASTER 430
6SE6400-5AF00-0BP0