Download Operation

Transcript
Trouble-Shooting
7.2
UMC-1 Universal Motor Controller LEDs
Problem
Cause
Remedy
READY LED illuminated red
Operating error on the UMC-1
go back to prior status
(radio channel was altered while switched on,
an attempt was made to switch off the UMC-1
while the camera was running)
Motor LED illuminated red
URM-1 with same radio channel active
select another radio channel
ZMU-1 or WMU-1 is switched off
switch on ZMU-1 or WMU-1
UMC-1 was switched on after ZMU-1
switch ZMU-1 or WMU-1 off and on again
or WMU-1
CLM-2 motor unit was connected after
switch off ZMU-1 or WMU-1 and UMC-1,
switching on ZMU-1 and/or WMU-1
switch on again and
recalibrate the system
Motor LED flashes red
106
Several motor units are set to the same
switch off, set selector switch on each motor
operational function or plugged into the UMC-1.
unit CLM-1 to the corresponding function,
The READY LEDs on the manual control units
or plug CLM-2 motor units into the
also flash red
corresponding position. Switch on.
CLM-2 motor unit defective
replace CLM-2 motor unit