Download PRISM 3000
Transcript
Figure 2-1 PRISM 3000 Rear Panel DC Version ON 2A 250 V OFF DCV RET GND 1 2 3 AC Version 110 /220 VAC 1.0A .4A /.2A ETHERNET ALARM RELAY l PORT 4 PORT 3 PORT 2 PORT 1 NMS IN O NMS SUPV STA OUT CLK NC C NO GND 4 5 6 7 8 T1 DTE T1 NET 9 10 11 12 13 14 Index Control/Indicator 1 DC Power Switch This switch turns the DC power ON or OFF. 2 DC Fuse This DC fuse is rated at 2.0 Amp. 3 DC Connection 48 VDC power is connected to ‘DCV’; the return is connected to ‘RET’. See Section 2.11.2 on page 2-6. 4 AC Connection This 110/220 VAC power receptacle is rated at 50-60 Hz, 0.6 A / 0.3 A. See Section 2.11.1 on page 2-6. 5 AC Fuse This AC fuse is rated at 1.0 Amp and is shipped with a spare. 6 AC Power Switch This switch controls the AC power (position I is ON and position O is OFF). 7 Alarm Relay The ‘Normally Closed’ alarm connects to NC & C. The ‘Normally Open’ alarm connects to NO & C. 8 NMS This is the network management system input/output. Refer to Section 2.10.1 on page 2-4. 9 SUPV Supervisory port connection. Refer to Section 2.10.2 on page 2-4. 10 Station Clock The N x 56/64 kHz or 1.544 MHz external station clock connector. Refer to Section 2.9 on page 2-3. 11 T1 DTE The T1 DTE port for drop and insert applications. Refer to Section 2.6 on page 2-3. 12 T1 NET The T1 network port. Refer to Section 2.7 on page 2-3. 13 Slot 1 - Ethernet This is the 15-pin Ethernet or Token Ring connection. Refer to Section 2.10.3 on page 2-5. 14 Ports 1 through 4 Two cards with up to two ports each may be inserted into each of these slots. Ports 1 and 2 show a combination of V.35 and EIA530 cards. 2-2 Installation Function PRISM 3000