Download GENLPLOT: for Display An Interactive Program and
Transcript
GENLPLOT Users Manual 3.3.9. 33 Changing the "Time" Base to a Different Type Typing TC at the Genl> prompt allows the user to change the time base to a different type. TC changes the "time" base to sample number by default. To change it to another type, like frequency for example, the TC command must be issued again whereupon a menu will prompt for the desired type. The TS command does the same thing. Genl> TC Change CCDIAMBS2P to sample number Genl> TC Transform sample number to ? 1 Time, msec 2 Sample Number 3 Frequency, kHz 4 Shot Number 5 Special Choice = 3 Change to Frequency, kHz Enter parameters DEL, AO for Genl> P A = DEL*n + AO > 1.0,0 Shot 16140 i i 1-Aug-1987 14:10 i i i iI iI 2000 II -a I .4 o.0 a Ii 5DO Ii 1LDO 15[I Fr.quen*6, Graf> 33 Idiz 3000 3600