Download IPDS™ Emulation Programmer`s Reference Manual
Transcript
Appendix C X'026402' Invalid LPD Unit-Base Explanation: On the Load Page Description command, the unit-base is not a valid or supported value. Alternate Exception Action: None X'026802' Invalid LPD Inline Direction Explanation: On a Load Page Description command the Inline Sequence Direction value is not a valid or supported value. Alternate Exception Action: Use an inline sequence direction of 0 degrees and a baseline sequence direction of 90 degrees. X'026902' Invalid LPD Baseline Direction Explanation: On a Load Page Description command the Baseline Sequence Direction value is not a valid or supported value. Alternate Exception Action: Use an inline sequence direction of 0 degrees and a baseline sequence direction of 90 degrees. X'026A01' Insufficient Source Image Data Explanation: The number of source image bytes received < the number implied in the Write Image Control command. Alternate Exception Action: None. X'026A02' Invalid LPD Initial Inline Coordinate Explanation: On a Load Page Description command, the initial inline coordinate value is not a valid or supported value. Alternate Exception Action: None X'026B01' Excess Source Image Data Explanation: The number of source image bytes received > the number implied in the Write Image Control command. Alternate Exception Action: None 74