Download uPD720101 DS - Renesas Electronics

Transcript
µPD720101
System clock ratings
Parameter
Clock frequency
Symbol
fCLK
Condition
X’tal
Min.
Typ.
Max.
Unit
−500
30
+500
MHz
ppm
Oscillator block
−500
ppm
48
ppm
Clock duty cycle
tDUTY
40
+500
MHz
ppm
50
60
%
Remarks 1. Recommended accuracy of clock frequency is ± 100 ppm.
2. Required accuracy of X’tal or oscillator block is including initial frequency accuracy, the spread of X’tal
capacitor loading, supply voltage, temperature, and aging, etc.
Data Sheet S16265EJ5V0DS
21