Transcript
Chapter 3 3.2. Eight Channel Models The Minimate Plus eight channel monitor offers a second set of four channels for compliance monitoring. A second microphone and a second standard transducer may be connected to these channels. For clarity, the number two (2) follows all references to the second microphone or second standard transducer throughout this manual. For most monitoring operations, setting up and using the monitor is the same for both four and eight channel models. Where differences do occur, this manual specifies both the four and eight channel procedures. Note: When using only four channels on eight channel monitors, always connect the sensors to channels one to four (CH 1–4). 3.3. Installing the Minimate Plus or the Standard Transducer The following sections apply to the Minimate Plus with a built–in transducer and the standard transducer as supplied by Instantel. The sections illustrate installation procedures recommended by Instantel. Your particular monitoring activities may employ one or a combination of all of the following procedures. You may even devise your own method for a specific application. It is important for you to couple the Minimate Plus or standard transducer securely to ensure reliable monitoring results. The following sections provide example installation methods. For wall and ceiling installations, refer to the Reference chapter. Other methods may be used if they satisfy the following requirements. 1. Arrow Pointed in Direction of the Event The arrow on the side of the Minimate Plus or on the top of the standard transducer must be pointed in the direction of the event to ensure the geophone sensors, located inside the Minimate Plus and standard transducer, remain in their natural axis. 2. Level Installation The Minimate Plus or the standard transducer must be installed level. For the Minimate Plus, a fastening plate is available. For the standard transducer, a leveling plate is available. Both the fastening plate and the leveling plate have three leveling feet and an integrated bubble level indicator. 3. Securely Coupled to the Surrounding Surface The Minimate Plus or the standard transducer must be securely coupled to the surrounding surface. The surface must be compact with no loose or soft material close to the Minimate Plus or the standard transducer. Coupling is critical for reliable and accurate monitoring results. Insufficient coupling allows the Minimate Plus or the standard transducer to move independently of the surrounding surface resulting in distorted, often higher, monitoring results. Coupling methods depend upon the type of surface with no single method applicable to all types. It is up to you to check the surface and mount the Minimate Plus or the standard transducer with sufficient coupling to ensure reliable monitoring results. 3–2 Minimate Plus Operator Manual