Download PROGRAM MANUAL_Rev5
Transcript
Instructor Station Revision 5 Via the NETWORK tab the following can be done: 5 - Start network computers remotely – REMOTE START: The network computers information is to be inputted into the “PCList.txt” file. Please input as follows: COMPUTER 1 0D00795F397E5 192.168.0.9 255.255.255.0 7 COMPUTER 2 [MAC Address] [IP Address] [Subnet mask] [Port No.] […] Choose whatever name you want MAC address of the computer’s LAN card IP address of the computer Subnet mask Port number. Important when accessing from outside a network router (you should enable this port in the router). This setting is not important when running all computers and the Instructor Station in a local network. Here is an example: COMPUTER ONE 0019DB6BA4FD 192.168.0.2 255.255.255.0 7 COMPUTER TWO 00805A62C8B6 192.168.0.3 255.255.255.0 7 Note that the format shown above needs to be respected (no dashes between digits in the MAC addresses, no blank lines between computers, etc.). Once this file is set up, the list of computers should appear in the Instructor Station Network Computers window. By selecting a computer and clicking "Start selected computer", the selected computer should start up. Also, by clicking on the "Network maintenance (s/u all computers)" all the computers on the list will be started up. IMPORTANT NOTE: Remote computer start up will work if: 1) The network card of each computer supports this feature (typically referred to as "Wake On LAN"). 2) If the network card/BIOS of each computer is appropriately configured to work in this way. 30-Jun-2014 Page 21 of 65