PHOTOMOD 6.0.2
Acceptable residuals are setup in the Parameters window on the Report tab (see Section 7.4 or Section 8.4).
Points selection by residuals value is performed using additional parameters Ground
XY, Ground Z, Tie XY, Tie Z.
Residuals are also could be displayed using checkboxes in the Show errors section of
the Display options window.
• In selected models – used to select points located in selection area of stereopair/strip
or multiple steropairs/strips:
○ At least one – points with measurements located in one selection area;
○ All – points with measurements located in all selection areas.
5.4. Points selection
Triangulation points on a block scheme could be selected using standard group selection
tools. To change the selection mode are used the Edit › Group selection menu and
the Tools toolbar. (see the Objects selection chapter of the “Vectorization” User
Manual).
Also the system provides possibility to highlight points of selected types on a block
scheme.
Click the
opened.
button to select points to be highlighted. The Select points window is
Fig. 4. The “Select points” window
To display points on a block scheme special – symbols.
13