Download User / Service - Avery Dennison

Transcript
Manual
TTX 300/COBRA Online
Remove board
For the TTX 300 board with the number 99670-xx-0 are used (different to the OFFLINE
board number 99671-xx-0 the IC’s 13,16,7 and 6 are not placed). Older versions of the
TTX 300 may use different board types.
unplug cables
pull board from the plastic snapper ( 1pcs ), loosen 2 screws from metal angle
and pull up the board
check new board to voltage adjustment
Pin 1
Pin 2
Pin 3
Pin 4
voltage to motor ~ 36 V (not adjustable)
Vcc 5 V (not adjustable)
voltage to print head (adjust with Pot P1 and Pot RV6 to 22V)
GND
Pin 1 Motor ~ 36 V
Pin 2 Vcc 5 V
Pin 3 Kopfsp. 22 V
Masse (Ground)
Transformer
for mounting / dismounting fix the inner metal bolt with a pair of pliers in order to
avoid twisting
03/02
Rev. 1.11
21