Platform Evaluation Kit Interface Card 6.1.1 PE0002 C-BUS Interface The C-BUS interface provides for the transfer of data and control or status information between the target device’s internal registers and the Microprocessor over the C-BUS serial bus. Each transaction consists of a single Register Address byte sent from the Microprocessor, which may be followed by one or more data byte(s) sent from the Microprocessor to be written into one of the target device’s registers, or one or more byte(s) of data read out from one of the target device’s registers, as illustrated in Figure 4. Figure 4 C-BUS Transactions 2012 CML Microsystems Plc 11 UM0002/5