Download 0 FRONT MATTER
Transcript
Reference Information Copper Inter-Enclosure GBIC (active) Connector: ................................... Style 1 (9 pin D-subminiature, DB-9) Style 2 (HSSDC, looks like wide phone jack or RJ45) Fibre Channel 100-TW-EL-S (shielded dual parallel pair cable) Fibre Channel 100-TP-EL-S (shielded dual twisted pair cable) Differential Impedance: ............... 150 ohms +/- 10 ohms Transmitted Signal:...................... 1100 - 2000 mV differential PECL Received Signal: .......................... 400 - 2000 mV differential PECL Distance: ...................................... 0 - 28 meters with 100-TP-EL-S cable 0 - 33 meters with 100-TW-EL-S cable Copper Intra-Enclosure GBIC (passive) Connector: ................................... Style 1 (9 pin D-subminiature, DB-9) Style 2 (HSSDC, looks like wide phone jack or RJ45) Cable:........................................... Fibre Channel 100-TW-EL-S (shielded dual parallel pair cable) Fibre Channel 100-TP-EL-S (shielded dual twisted pair cable) Differential Impedance: ............... 150 ohms +/- 10 ohms Transmitted Signal:...................... 600 - 2000 mV differential PECL Received Signal: .......................... 400 - 2000 mV differential PECL Distance: ...................................... 0 - 11 meters with 100-TP-EL-S cable 0 - 13 meters with 100-TW-EL-S cable GigWorks MKII-8 Switch Model MKII-BASE8 Installer's/User's Manual 59004-01 Rev. A Reference Information A-7