April 2004 Installing and Orienting the Junction Box Before placing the BWT transducer into the FSPA/FWPA Buffer permanently, you must make sure the preamplifier junction box will be properly oriented once installed. Note: The following drawings show the FSPA Buffer only. 1. Screw the transducer into the junction box as shown below. 2. Screw the transducer/junction box assembly into the FSPA/FWPA Buffer. 3. Check the junction box orientation. The junction box lid should be at a downward angle so water can drain. If it is not, adjust the junction box until it does. OK Good Bad 4. Remove the transducer/junction box assembly. 5. Repeat the above steps for the other transducer. Installing Non-Flanged FSPA/FWPA BWT Buffers and Transducers 4-3