ENG 8. ALARMS pRack PR100 can manage both alarms relating to the status of the digital inputs and to operation of the system. For each alarm, the following are controlled: • The actions on the devices, if necessary • The output relays (one global and two with different priorities, if configured) • The red LED on the terminal and the buzzer, where present • The type of acknowledgement (automatic, manual, semiautomatic) • Any activation delay 8.1.3 • by pressing the (Alarm) button and then (Enter) when there are no active alarms • by pressing (Enter) after having scrolled all the alarms. The alarm log screens show: Order of activation (no. 01 is the oldest alarm) Hour and date the alarm was activated Short description Main values recorded at the moment the alarm was activated (suction pressure and condensing pressure) Note: A maximum of 50 alarms can be logged; after this limit any new events overwrite the oldest ones, which are therefore deleted. 1. 2. 3. 4. The complete list of alarms, with the related information as described above, is available in Appendix A.4. 8.1 Alarm management All alarms feature the following behaviour: • When an alarm is activated, the red LED flashes and the buzzer is activated (where present); the output relays corresponding to the global alarm and to any alarms with priority are activated (if configured) 8.2 Compressor alarms The number of alarms for each compressor can be set during the configuration phase using the Wizard or subsequently from branch C.a.e/ C.b.e of the main menu. The number of alarms is the same for all the compressors on the same line. • Pressing the (Alarm) button, the red LED stays on steady, the buzzer is muted and the alarm screen is shown • If there is more than one active alarm, these can be scrolled using (Up) (Down). This condition is signalled by an arrow at the bottom right of the screen Alarms • Pressing the (Alarm) button again for at least 3 seconds acknowledges the alarms manually, and these are cleared from the display unless others are active (they are saved in the log) 8.1.1 Cae01 Number of alarms for each compressor: 3 Priority For certain alarms, the alarm output relay can be set with two types of priority: • R1: serious alarm • R2: normal alarm The corresponding relays, once configured, are activated when an alarm with the corresponding priority occurs. For the other alarms, the priority is fixed and is associated by default with one of the two relays. 8.1.2 Log The alarm log can be accessed: • from branch G.a of the main menu Fig. 8.a Note: The maximum number of alarms that can be configured for each compressor depends not only on the type of compressor, but also on the size of pRack and the number of compressors fitted. After having selected the number of alarms (maximum 4 for the reciprocating or scroll compressors and 7 for screw compressors), the settings can be configured for each alarm, choosing a description from the options shown in the table, the output relay, the type of reset, delay and priority. The effect of the alarm on the devices is set and involves stopping the compressor, except for the oil warning. Acknowledgement The alarms can have acknowledgement: manual, automatic or semiautomatic • Manual: the alarm is acknowledged by pressing the (Alarm) button twice, the first time displays the corresponding alarm screen and mutes the buzzer, the second (extended, for at least 3 seconds) cancels the alarm (which is saved in the log). If the alarm is still active, acknowledgement has no effect and the signal is shown again. • Automatic: when the alarm condition ceases, the alarm is automatically reset, the LED comes on steady and the corresponding screen remains Possible descriptions for compressor alarms Reciprocating or scroll Generic Overload High pressure Low pressure Oil displayed until the (Alarm) button is pressed and held; the alarm is saved in the log. • Semiautomatic: acknowledgement is automatic, until a maximum number of activations in set time. If the number reaches the maximum set, acknowledgement becomes manual. For manual acknowledgement, the functions associated with the alarm are not reactivated until acknowledgement has been completed, while for automatic acknowledgement they’re reactivated as soon as the alarm condition ceases. Screw Generic Overload High pressure Low pressure Oil Screw rotation Oil warning (Filter Blocked) Tab. 8.a An example of a screen for selecting the description of the alarm is shown in the figure: Alarms Cae02 Alarm 1 description: Generic: Overload: High pressure: Low pressure: Oil: Fig. 8.b 69 pRack +0300011EN rel. 1.2 - 04.12.2012