SteppIR SARK-110 Appendix E: User’s Manual Frequency Calibration This setup permits the frequency synthesizer to be calibrated to 1 Hz. The calibration operation is available at «Setup» «Calibration» «Frequency Calibration». To calibrate the synthesizer, select «Frequency Calibration» from the «Calibration» submenu and adjust the frequency while measuring it with an accurate frequency counter or, alternatively, zerobeat it against WWV. Use Navigator B to change the frequency. The frequency will change according to the current frequency multiplier that is highlighted in reverse video. Use Navigator A to change the frequency multiplier position if needed. When an exact 10 MHz output is obtained, press the Select [■] button to permanently store the setting. Ø For best accuracy, allow the unit to be turned on for at least 10 or 15 minutes. Press the Save Screen [●] button if the default setting needs to be restored. Rev 1.1.7 October 29th, 2014 - 71 - © Melchor Varela – EA4FRB 2011-2014