Download RxT 10GE User`s Manual
Transcript
RxT 10GE User's Manual RFC2544 Back-to-Back Testing Notes At the start of the test, the RxT 10GE will send frames back-to-back for the specified duration. • If the test runs without losing frames, the duration will be increased and the test redone until frames are lost or until the maximum duration is reached. • If frames are lost, the duration will be reduced until no frames are lost. • This cycle will continue until the specified resolution is reached. • Once completed, this is counted as one repetition; the test is then repeated, starting at the original duration, for the number of repetitions specified. Where do you want to go next? RFC2544 RFC2544 RFC2544 RFC2544 RFC2544 index Back-to-Back Setup Throughput Test Setup NE Stress Test Configuration Applications Summary Results RFC2544 Throughput Latency Setup Select RFC2544/NE Test as the test type on the RFC2544 Signal setup window to perform RFC-2544 tests. Throughput/(Quick) Latency - NE Parameter Options Details Duration Time, Frames Set how measurements will be taken. TIME: Base measurements on a length of time. FRAMES: Base measurements on a number of frames Duration = Frames Frames Time Start Rate 10/100M: N/A • GigE Options: 10,0001,000,000 • 10GE Options: 10,00010,000,00 0 4-60 seconds .01-100% Stop Rate 01-100% 104 • Duration = Time Set the rate at which frames will begin being transmitted. • 100% is a good starting rate for a standard RFC test, recommended in RFC 2544. • For NE testing, select the rate applicable to your setup. Set the rate at which frames will stop being transmitted. 100% is typical.