Pacific Research 4.5.36 RI-100 User Manual REGENERATE DTMF TONES FROM THE AUXILIARY INPUT This command selects if DTMF tones from the auxiliary input will be regenerated on the local repeater or link transmitter. Regenerated DTMF tones are 150 ms long immediately following the end of the DTMF decoded string from another controller. With DTMF Mute On (S-Command 17 and 33) you can always pass quality DTMF tones to your link with this regenerate mode. SYNTAX: MINIMUM: MAXIMUM: UNITS: DEFAULT: EXAMPLE: 4.5.37 36 [Mode] 0 1 1 = On and 0 = Off 0 36 1 Mode 1, regenerate DTMF digits on output from auxiliary input. MULTIPLE CONTROLLER DATA LINK PROTOCOL MODE This command is used to setup the method for multiple repeater controller to communicate. Mode 0 is typically used when connecting to someone else’s controller. The TTL level input and output digital signals are LOW TRUE or LOW ACTIVE. The COS input is the same as the RXD input and the PTT output is the same as TXD output. Mode 1 is used when connecting multiple RI-200 (or one RI-200 and one RI-100) repeater controllers together. In mode 1 the controllers communicate to each other using serial data. Also in this mode macro data from one controller can be used to function another controller. SYNTAX: MINIMUM: MAXIMUM: UNITS: 37 [Mode] 0 1 Mode 0 = Digital I/O Mode 1 = Serial Data I/O DEFAULT: 1 EXAMPLE: 37 0 Mode 0 selects the digital state port. 4.5.38 RI-200 CONTROLLER UNIT ADDRESS This command is used to assign a RI-200 its unique address when more than 2 controllers are connected together. The unit address is used in a protocol when 2 or more controllers are setup to talk to each other. Valid unit addresses are 1 through 9 with default being 1. A controller with an S-command address in its macro will not process that S-Command, all other controllers will look for a matching address and execute the S-command. An externally executable S-command starts with the “A” prefix and a number like “A2”. This will send the S-command following the A2 to all connected controllers with the unit address of “2”. When connecting more than 2 controllers, you will have to assign each controller its own address. When only two controllers are connected, both controllers can have the same unit address if they are only talking to each other. SYNTAX: MINIMUM: MAXIMUM: UNITS: DEFAULT: EXAMPLE: 38 [Address] 1 9 Unit address 1 38 3 Sets controller unit address to 3. Page 31