Download Hydra Ice User Guide

Transcript
NOTE 3: You should NEVER disconnect the red receiver wire on the Hydra Ice2 HV200™ ESC. It does not have an integrated BEC so all wires
must be in place for proper controller operation. Disconnecting the red wire will render the controller inoperable.
NOTE 4: Always power your radio transmitter before powering up the receiver and/or the ESC. Some receivers with failsafe features or
Spektrum receiver units that are not bound on receiver power up are entirely capable of causing the arming sequence to occur and command
the ESC to drive the motor. Always keep the boat on a stand and clear of body parts when the ESC is powered.
NOTE 5: Always perform a range check at full, half, and zero throttle before operating your model with any new speed controller!
NOTE: When setting LiPo cutoff voltage follow your battery manufacturer’s recommendations!
Castle Creations is not responsible for damage to batteries due to improper cutoff voltage.
9.0 PROGRAMMABLE FEATURES
NOTE: Factory Defaults are indicated by asterisk (*)
Hydra Ice 240™
1. Reverse Type
2. Reverse Throttle Amount
3. Cutoff Voltage
4. Auto-LiPo Volts/cell
5. Motor Rotation Direction
6. Motor Timing
7) Throttle Dead Band
1. Forward Only*
No reverse function
2. Forward to Reverse
Forward and reverse function
1. 12.5%
Maximum reverse speed equal to 12.5% of full power
2. 25%
Maximum reverse speed equal to 25% of full power
3. 50%*
Maximum reverse speed equal to 50% of full power
4. 100%
Maximum reverse speed equal to 100% of full power
1. None
NiCad/NiMH cells ONLY!
2. Auto-LiPo*
Automatically sets cutoff voltage to 3.2v/cell
3. 6v
2s (2 cell) LiPo
4. 9v
3s (3 cell) LiPo
5. 12v
4s (4 cell) LiPo
6. 18v
6s (6 cell) LiPo
1. 3.0v
Cuts off LiPo pack(s) at 3v/cell
2. 3.1v
Cuts off LiPo pack(s) at 3.1v/cell
3. 3.2v*
Cuts off LiPo pack(s) at 3.2v/cell
4. 3.3v
Cuts off LiPo pack(s) at 3.3v/cell
5. 3.4v
Cuts off LiPo pack(s) at 3.4v/cell
6. 3.5v
Cuts off LiPo pack(s) at 3.5v/cell
1. Forward*
Rotates motor forward
2. Reverse
Rotates motor in reverse
1. Low
Maximum efficiency/runtime
2. Normal*
Balance of power/runtime
3. Race
More power/less runtime/more motor heat! No warranty!
1. 0.15ms
Very wide
2. 0.10ms*
Average
3. 0.075
Small
4. 0.050
Smaller
5. 0.025
Very small
1. Forward only*
No reverse function
2. Forward to Reverse
Forward and reverse function
Hydra Ice2 HV200™
1. Reverse Type
Continued on the next page.
Hydra Ice™ User Guide
© 2012 Castle Creations, Inc. All rights reserved.
Page 6