3
User Controls/Connections
Locating Modes:
Power mode
Radio mode
33kHz Active
131kHz Active
Sonde mode
Metal cover detection mode
3.1.3Warning/Alerts
Warnings or alerts can be indicated by four different methods:
1. Audio - an audible warning sound will be emitted.
2. Vibe - a vibration device situated in the handle will activate.
3. Visual - an alert icon will replace the battery icon.
4. Shutdown – the vScan can be configured to shut down if the management or user decides that is the most appropriate
course of action (examples – if self-test and calibration verification fails, or a “rental” period ends).
NOTE
The vScan will continue to operate in a warning/alert condition unless configured to “shut down”. If
an overload condition is triggered the bar graph will also flash.
How warnings/alarms communicate their message is user configurable using MyvScan desktop application.
3.1.3.1 Shallow Line Alert
The shallow line alert will be triggered when a shallow line is detected.
3.1.3.2 Swing Alert
The swing alert will trigger if the angle of swing exceeds 30 degrees from the vertical. No alarm will be
activated if the angle is more than 65 degrees from the vertical as it will be assumed that the locator is not in
use at this time.
™