Transcript
4.2.3 ATEST PROCEDURE a. The EUT was placed 0.4 meters from the conducting wall of the shielded room and connected to the power mains through a line impedance stabilization network (LISN). Other support units were connected to the power mains through another LISN. b. Voltage at the measurement port of the ISN was detected, the reading was corrected by adding the voltage division factor of the ISN, and was compared to the voltage limits. c. The disturbance levels and the frequencies of at least six highest disturbances were recorded from each telecommunication port which comprises the EUT. 4.2.4 DEVIATION FROM TEST STANDARD No deviation l : The test Configuration was defined by the applicant requirement. cording to the Note 3 of Table 4 of CISPR 22:1997/EN 55022:1998, a relaxation of 10 dB over tz. For B equipment, a relaxation of 10 dB over the referency range of 6 MHz to 30 MHz is allowed for high speed services having significant spectral density in this ba Report No.: CE941006H04B Reference No.: 941219H04 21 Report Format Version 2.0.4