Download DC6000 Data Recorder - User Manual and Reference
Transcript
Section 5 – Recorder Setup 5.3.2 Bar Graphs There are four types of bar graph widgets, two horizontal and two vertical with full size and half size versions of each. Up to 8 full size horizontal and 16 half size horizontal bar graphs can be placed on the GUI. Up to 6 full size vertical and 12 half size vertical bar graphs can be placed on the GUI. The full size vertical bar widget is 1 block across by 8 blocks tall. It shows up to 8 characters of Channel Tag and Engineering units. It has a 5 character Digital readout The half size vertical bar widget is 1 block across by 4 blocks tall. It shows up to 8 characters of Channel Tag and Engineering units. It has a 5 character Digital readout The full size horizontal bar widget is 6 blocks across by 1 block tall. It shows up to 8 characters of Channel Tag and Engineering units. It has a 5 character Digital readout The full size horizontal bar widget is 3 blocks across by 1 block tall. It shows up to 8 characters of Channel Tag and Engineering units. It has no Digital readout 5.3.2.1 Bar Graph Setup The Bar Graph Display Edit dialog window will pop up when setting up a display using the Display Builder or can be invoked at any time by double-tapping the scale on the bar graph widget on the screen. The dialog box shows the Channel Number (2) and the Channel Type (Horizontal BAR Full). The user can use this window to change appearance parameters of the Bar Graph widget or can proceed beyond to fully set up or edit the channel information. Channel: Shows the current Channel assigned to the widget. The user can change the assignment by selecting a different channel from the drop down list. Channel Type: Shows the current widget style for the channel. For information only. Figure 5-3-2 Bar Graph Display Edit Enable: When checked the Bar Graph is active, when unchecked it is off and the Display will show OFF. Point Tag: This is a description for the channel point and defaults to the Channel Setup value. It can be changed for this Bar Graph. User can enter up to 8 characters Eng Units: This is the Engineering Units for the channel and defaults to the Channel Setup value. It can be changed for this Bar Graph. User can enter up to 7 characters Color: Used to set the color of the BAR in the Bar Graph widget and defaults to the Channel Setup value. It can be changed for this Bar Graph. BackGround Color: Used to set the Background color for the Bar Chart and defaults to the Channel Setup value. It can be changed for this Bar Graph. Dec Pt.: Decimal Points – Select number of places after the decimal point to display on the Bar Graph widget. Scale: This is used to customize the local scale on the Bar Chart widget. In the above example, the input is a J Type Thermocouple which has an actual scale of -346 to 2192 °F. For this bar chart it has been set Page 54 04/15/2009 REV 1.00.3