Download "user manual"

Transcript
JEMWare Meter Configuration Software
NOTE: When sharing a single configuration file among multiple meters, be sure to verify
that the gain corrections are correct for all meters, or else edit them to the appropriate
value for the meter about to be programmed.
Display Registers
This menu choice allows the user to determine which electrical quantities are to be stored
in the meter‘s memory (registers). The information in the Display Registers can be
viewed on the meter‘s LCD panel and also can be read via serial communications. In the
JEMStar, there are 50 Normal registers, 50 Alternate registers, and 50 Test registers
available. The Ci20 meter has a total of 50 registers available distributed between
Normal and Alternate and 50 Test Registers. Normal and Alternate registers can be used
interchangeably to store any parameters. It is your choice whether to assign a quantity to
a Normal or Alternate register, and it is simply a preference to sort functions as you
choose. The Test registers are for temporary storage and only used when in the Test
Mode. All the data in a Test register is cleared when Test Mode is exited.
20