JEMWare Meter Configuration Software NOTE: When sharing a single configuration file among multiple meters, be sure to verify that the gain corrections are correct for all meters, or else edit them to the appropriate value for the meter about to be programmed. Display Registers This menu choice allows the user to determine which electrical quantities are to be stored in the meter‘s memory (registers). The information in the Display Registers can be viewed on the meter‘s LCD panel and also can be read via serial communications. In the JEMStar, there are 50 Normal registers, 50 Alternate registers, and 50 Test registers available. The Ci20 meter has a total of 50 registers available distributed between Normal and Alternate and 50 Test Registers. Normal and Alternate registers can be used interchangeably to store any parameters. It is your choice whether to assign a quantity to a Normal or Alternate register, and it is simply a preference to sort functions as you choose. The Test registers are for temporary storage and only used when in the Test Mode. All the data in a Test register is cleared when Test Mode is exited. 20