Download GMS User Manual (v9.1)
Transcript
Model Calibration 546 Calibration, Parameters, Stochastic Modeling Calibration Model Calibration Automated Parameter Estimation Parameter Estimation Dialog PEST Run Options Observations Plot Wizard Calibration Targets Parameters Parameters Parameter Dialog Pilot Points Multiplier Arrays for Parameters Standard MODFLOW Parameters Stochastic Modeling Stochastic Modeling Gaussian Field Generator Risk Analysis Wizard T-PROGS Calibration is the process of modifying the input parameters to a groundwater model until the output from the model matches an observed set of data. GMS includes a suite of tools to assist in the process of calibrating a groundwater model. Both point and flux observations are supported. When a computed solution is imported to GMS, the point and flux residual errors are plotted on a set of calibration targets and a variety of plots can be generated showing overall calibration statistics. Most of the calibration tools can be used with any of the models in GMS. Automated Parameter Estimation is supported for MODFLOW models via PEST. Two types of observations can be defined in GMS: point observations and flow observations. Both types of observations are defined in the map module and are associated with points, arcs, and polygons. Point observations represent locations in the field where some value has been observed. In most cases, the points will correspond to observation wells and the value will be the elevation of the groundwater table (the head). Flow observations represent linear or areal objects such as streams and reservoirs where the gain or loss between the aquifer and the object has been measured or estimated. Both point and flow observations can be assigned a confidence interval or calibration target. While point observations can be used with any model, flow observations can only be used with MODFLOW. Once a set of observed point and flow values has been entered, each time a model solution is imported, GMS automatically interpolates the computed solution to the observation points. For some models (MODFLOW) the model outputs the computed values at the observation points. Also, MODFLOW outputs the computed flow for the flow observations. A calibration target representing the magnitude of the residual error is displayed next to each observation point and each flow object as shown below. The size of the target is based on the confidence interval or
Related documents
GMS User Manual (v8.3)
PROGRAMME - Bibliothèque Départementale de la Manche
Groundwater Modeling System GMS v3.0 REFERENCE
Guia Avançado Uso do Programa GPS TrackMaker® com os
Groundwater Modeling System GMS v3.0 TUTORIALS
HY-8 User Manual (v7.3)
Visual MODFLOW Premium
Groundwater Modeling System TUTORIALS Volume III GMS version
The Literate Programming FAQ
TUTORIALS Volume II GMS version 5.0
718 30G/100G - Electrocomponents
Model 787 - Transcat