Appendix D How to Use PLC Function| Explanations: When the RST command is driven, motion of its specific device is as follows: Device Status Y, M Coil and contact will be set to “OFF”. T, C Present values of the timer or counter will be set to 0, and the coil and contact will be set to “OFF.” D The content value will be set to 0. Program Example: Ladder diagram: Command code: Operation: X0 RST Y5 LD X0 Load contact A of X0 RST Y5 Clear contact Y5 Mnemonic Function TMR 16-bit timer Operand T-K T0~T15, K0~K32,767 T-D T0~T15, D0~D29 Explanations: When TMR command is executed, the specific coil of timer is ON and timer will start to count. When the setting value of timer is attained (counting value >= setting value), the contact will be as following: NO(Normally Open) contact Open collector NC(Normally Closed) contact Close collector Program Example: Ladder diagram: X0 TMR T5 K1000 Command code: Operation: LD X0 Load contact A of X0 T5 timer TMR T5 K1000 Setting is K1000 Revision Jan. 2009, 06EE, SW--PW V1.12/CTL V2.12 D-37