Download user manual

Transcript
64
Appendices
MoTeC
Appendix E: Update Rate Summary
The following table shows the maximum update rates for the various
measurement devices
Device
Input Type
Maximum
Update Rate
(per second)
ACL
RS232 Communications
200 *
ACL
General CAN communications
200 *
VIM
AV Fast Inputs
5000
VIM
AV Differential Voltage Inputs
1000
VIM
AV High Resolution Inputs
500
VIM
AV Special Inputs
2000
VIM
Speed Inputs
100
ADL2/SDL
Analogue Voltage Inputs 1 to 4
(ADL2/SDL) and 11 to 14 (ADL2)
1000
ADL2/SDL
Other Analogue Voltage Inputs
500
ADL2/SDL
Analogue Temperature Inputs
500
ADL2/SDL
Lambda Inputs
100
ADL2/SDL
Digital & Speed Inputs
100
SDL
Internal G Sensors
100
E888
Thermocouple Inputs
(First Device / Second Device)
100 / 50
E888/816
Analogue Voltage & Digital Inputs
(First Device / Second Device)
200 / 50
*RS232 & General CAN Communications update rate depends on how
frequently the data is sent from the device. Typically the update rate from an
M4, M48, M8 or M800 ECU is about 20 times per second using RS232 and
about 50 times per second for the M800 using CAN.