Download user manual
Transcript
16 Operation MoTeC General Purpose Calculations: The ACL also provides a number of general purpose calculations including: • 2D and 3D Lookup Tables • User Defined Conditions • General Purpose Timers • Mathematics • Bit Combine • PID Control The user defined conditions or tables can be used to activate items such as a Thermatic Fan or Gearbox Oil Pump. For details on all calculations refer to the help in ACL Manager. Measurement Inputs The ACL’s external measurement devices have inputs that can be connected to a wide variety of sensors. Sensors Different types of sensors are available to suit different types of measurements, for example: temperature, pressure, movement etc. Sensors convert a physical measurement (e.g. pressure) into an electrical signal (e.g. volts). Different types of sensors generate different types of electrical signals. For example most temperature sensors convert the temperature into a variable resistance which may be measured by an Analogue Temperature input, however most wheel speed sensors generate a variable frequency signal which must be connected to either a Digital input or a Speed input. Sensor Amplifiers Some sensors may require an amplifier to be connected between their output and the measurement device input. This will depend on whether the measurement device supports direct measurement of the particular type of sensor. For example an ADL2 does not allow direct measurement of thermocouples whereas both the E888 and VIM do.