An alternate method is to go to the recorder, save the setup on a media (even if it is blank), and import the setup to the Trend Analysis software. This way the hardware configuration, number of virtual pens, modbus number, and the serial and ID numbers are correct form the beginning. It also helps reduce setup time if the customer wants to do real-time communications. NB. Add New Device functionality is not applicable for the Archived Databases from the Archive Database Server. Hardware Setup In the “Add new device” box there are slot references that co-ordinate with the slots on the rear panel of the recorder. Select the drop down list in each slot for Analogue IO/ Pulse In cards, this hardwaresetup must match the recorder configuration. Select the correct card description for each slot and the channels number, if there is no card fitted Select None. (Analogue Output and Pulse input cards are not available for the QXe, GR1 recorder) Alarm/Digital IO Card Setup If fitted, select the type of Alarm/Digital IO cards that will match the recorder’s set up. Select the correct card description for each slot and the channel numbers, if there is no card fitted select None. 54 43-TV-25-25 GLO Issue 17 July 2014 UK