Features This section provides a brief overview of the Captioning Module features. Data IDs The Data ID and Secondary Data ID fields specify the hexadecimal values to be used for the corresponding fields in the encoded Ancillary Data Packet, as defined by SMPTE 291M. It should be noted that the TES9 is shipped with these fields set to the values specified by SMPTE 334M (61/1), and therefore it is normally not necessary for the user to change these fields. Line Selection For Line Selection, radio buttons are used to select the chroma or luma channel. The VANC line is selected using a pull down list. Caption Service Information Defaults The fields in this section specify the data for the Closed Caption Service Information for each caption service being inserted. The Language field specifies the 3-character language code as given in ISO 639.2/B. The Easy Reader check box indicates that the closed caption service contains text tailored to the needs of beginning readers. TES9 Software User Manual (Iss. 03) Captioning Module • 5–3