Input of data to the local database Export the original .ttd file in TinyTag Explorer. Press [View] [Table of readings] and [File] [Export] [All cells] - Use the same filename and save it as a text file (.txt). TinyTag data are saved in the folder (GeoBasis/TinyTag/YYYY/SS_YYYY) (SS=site YYYY= year). Files are split into calendar years (1 January to 31 December). Open the text files in Excel and copy data in order to fulfil the worksheet from the previous year and start a new file for the actual year. Quick validation of data Make a plot for the calendar year. Control the data quality: Check that the time series are adequate and that the temperature interval looks reasonable. Remove defect data and single outliers from the dataset. Interpolate values where single data are missing. Record every manipulation under Remarks. If the data file is complete and looks satisfactory, calculate minimum, maximum and mean temperature. Save statistic results in the worksheet “TinyTag statistic” (GeoBasis/TinyTags/Tinytag statistic). Add information about each TinyTag logger in the file “TinyTag logbook” (GeoBasis/TinyTags/TinyTag logbook). Troubleshooting If communication fails: Try to change the battery or try to leave the data logger open for drying If you bring the logger inside from the cold – do not open until it has reached room temperature in order to prevent condensation. Check that you have attached the cable at the right plug on the logger. 5.2 Geo-Precision permafrost temperature In September 2012 ten Geo-Precision temperature strings were installed in different settings around the Zackenberg valley. Two of these installations are deep boreholes while the remaining are shallow (2m - 5m) satellite boreholes. The installations record ground temperatures in different locations throughout the valley allowing a broader view of the ground thermal regime within the valley. All sites are instrumented with Geo-Precision thermistor strings and data loggers. These systems are quite simple to operate. The whole system is one cylindrical logger (either stainless steel or black plastic) attached by a screw on tri-pin connector to the thermistor chain. Location and coordinates of the logger sites are shown in fig. 5.2 and table 5.1. Below is a short manual on how to offload data. Further information about the sites and maintenance can be found in the manual by Jordan R. Mertes:” Zackenberg Geo-Precision Permafrost Temperature Sensors”, which can be found I House 4. 49