Download GeoBasis - Zackenberg Research Station

Transcript
Input of data to the local database
Export the original .ttd file in TinyTag Explorer. Press [View] [Table of readings] and [File] [Export]
[All cells] - Use the same filename and save it as a text file (.txt).
TinyTag data are saved in the folder (GeoBasis/TinyTag/YYYY/SS_YYYY) (SS=site YYYY= year).
Files are split into calendar years (1 January to 31 December). Open the text files in Excel and copy
data in order to fulfil the worksheet from the previous year and start a new file for the actual year.
Quick validation of data
Make a plot for the calendar year.
Control the data quality: Check that the time series are adequate and that the temperature
interval looks reasonable.
Remove defect data and single outliers from the dataset. Interpolate values where single
data are missing.
Record every manipulation under Remarks. If the data file is complete and looks
satisfactory, calculate minimum, maximum and mean temperature. Save statistic results in
the worksheet “TinyTag statistic” (GeoBasis/TinyTags/Tinytag statistic).
Add information about each TinyTag logger in the file “TinyTag logbook”
(GeoBasis/TinyTags/TinyTag logbook).
Troubleshooting
If communication fails:
Try to change the battery or try to leave the data logger open for drying
If you bring the logger inside from the cold – do not open until it has reached room
temperature in order to prevent condensation.
Check that you have attached the cable at the right plug on the logger.
5.2 Geo-Precision permafrost temperature
In September 2012 ten Geo-Precision temperature strings were installed in different settings
around the Zackenberg valley. Two of these installations are deep boreholes while the remaining
are shallow (2m - 5m) satellite boreholes. The installations record ground temperatures in
different locations throughout the valley allowing a broader view of the ground thermal regime
within the valley. All sites are instrumented with Geo-Precision thermistor strings and data
loggers. These systems are quite simple to operate. The whole system is one cylindrical logger
(either stainless steel or black plastic) attached by a screw on tri-pin connector to the thermistor
chain. Location and coordinates of the logger sites are shown in fig. 5.2 and table 5.1. Below is a
short manual on how to offload data. Further information about the sites and maintenance can be
found in the manual by Jordan R. Mertes:” Zackenberg Geo-Precision Permafrost Temperature
Sensors”, which can be found I House 4.
49