Chapter 2 Configuration and Installation The configuration for jumper W5 specifies whether a board is to drive the onboard 10-MHz oscillator onto the RTSI bus, receive the RTSI bus clock, or disconnect from the RTSI bus clock. This clock source, whether local or RTSI signal, is then divided by 10 and used as the Am9513A frequency source. The jumper selections are listed in Table 2-9. Table 2-9. Configurations for RTSI Bus Clock Selection Configuration W5 Disconnect board from RTSI bus clock; use local oscillator C - D, E - F (factory setting) Receive RTSI bus clock signal A - B, E - F Drive RTSI bus clock signal with local oscillator A - B, C - D BRD BRD NC Figures 2-21, 2-22, and 2-23 show the jumper positions for each of the configurations described above. • • RTSI 10 MHZ NC W5 BRD BRD NC Figure 2-21. Disconnect from RTSI Bus Clock; Use Onboard Oscillator (Factory Setting) • • RTSI 10 MHZ NC W5 Figure 2-22. Receive RTSI Bus Clock Signal © National Instruments Corporation 2-19 AT-MIO-16D User Manual