Network Menu Reference
14.2 Multiple Controllers
14.2.1 Overview and Menu Options
The Lake Controller system allows multiple Controllers to be connected to the same network. When in this
mode, certain functionality is restricted.
The first Controller to connect to a network is called the primary Controller. Any subsequent Controllers are
referred to as secondary Controllers.
The following options are available on the Multiple Controllers submenu:
14.2.1.1 Multi Cont Enable
This button is available only on the primary Controller and is disabled (gray) on any secondary Controllers.
When this button is active (orange), multiple Controllers are allowed on the same network. When the button
is inactive (blue), only one Controller is allowed on the network.
14.2.1.2 Confirmation Required
This button is available only on the primary Controller and is disabled (gray) on any secondary Controllers.
When this button is active (orange), a confirmation dialog box is displayed on the primary Controller when a
secondary Controller attempts to connect. If this button is inactive (blue), then additional Controllers are able
to connect to the network without primary Controller approval.
14.2.1.3 Analyzer Enable
This button provides the option to disable analyzer data on a per-controller basis (useful when using multiple
Controllers). If this button is active (orange), analyzer data will be displayed on this Controller. If this button
is inactive (blue), analyzer data will not be displayed. This button is disabled (gray) if the analyzer or Analyzer
Bridge is not available.
14.2.2 Primary and Secondary Controllers
The primary Lake Controller communicates with the network of Processors, and also with secondary
Controllers. The secondary Controllers communicate only via the primary Controller.
The primary Controller can be used in either Designer or User Mode (in which various Designer Mode
functions will be restricted). Secondary Controllers are always restricted to a limited version of User Mode
operation.
The primary Controller must have a connection to the network for secondary Controllers to function.
Lake Controller Operation Manual rev 1.2.3
185