Download 6500-6.5.19, Pro-Set 700 Co-injection Software, User Manual

Transcript
A–34
Reference Information
Injection Profile Setup Screen
Here are the tag names and PLC processor addressses for the
Injection Profile screen.
Important: If the profile control mode is Velocity vs. Pressure or
Position, the velocity and position of unused setpoints
are set to 0 (zero). If the profile control mode is
Pressure vs. Pressure or Position, the pressure and
position of unused setpoints are set to 0 (zero).
Field name
Publication 65006.5.19 - January, 1996
Field Type
Selection
Tag Name
PLC Processor
Address
Number of
Segments
Popup
selection
1 through 11
INCB.SEG_NUM
N24:44
Proportional
Gain for
Pressure
Numeric
entry
0 - 99.99
INCB._49
N128:45
Integral Gain
for Pressure
Numeric
entry
0 - 99.99
INCB._50
N128:46
Derivative
Gain for
pressure
Numeric
entry
0 - 99.99
INCB._51
N128:47
Proportional
Gain for
Velocity
Numeric
entry
0 - 99.99
INCB._52
N128:48
Feedforward
Gain for
Velocity
Numeric
entry
0 - 99.99
INCB._53
N128:49
Pressure
Numeric
Limiting Time entry
Delay
0 - 99.99
seconds
IPCB._59
N128:115