TSTAT Floor Thermostat
Owner’s Guide
Select the
operating
mode and
exit a
function
Time and
day settings
Current
time and
day
Introduction
Floor temperature.
(arrow indicates a
setpoint
adjustment/view)
Heating
indicator is
displayed
when heating
is ON.
Comfort
and
Economy
setpoints
Temperature
and options
selection
Schedule programming
and advanced settings
Current
program when
Auto mode is
activated
LO: The temperature is below -10°C.
The heating indicator
is
displayed and the relay is closed
(energized). The screen will display
the floor temperature when it rises
above -10°C.
HI: The floor temperature is above 60°C. The floor
temperature will be displayed when it drops below
60°C.
The floor sensor is defective:
E1: The floor sensor is not connected
properly or is open circuit.
E2: The floor sensor is short circuited.
If this situation occurs, you can configure
the thermostat to operate like a regulator.
Control module
On/Standby Feature
The thermostat has an On/Standby feature making it
possible to put the thermostat in sleep mode when its use
is not required (e.g. summer).
The convenient backlight will light at the press of any
button and will stay on for 12 seconds.
Manual
Mode
Standby
Mode
Note: Keep the thermostat's air vents clean and free from
obstructions.
Note: The screw cannot be removed completely.
Clock and Day Settings
See “Advanced Programming” for more information.
Follow these steps to set the current time and day:
n
o
p
q
r
s
t
Power base
Automatic
Mode
Press any key to activate the display backlight
First Power On
Temperature reading is above or below display
limits:
Align the bracket tabs on the control module with the
holes located on top of the power base.
Display with Backlight
Pre-defined
Comfort and
Economy
Setpoints
On the first installation, the screen
displays: 0:00, MO,
and the floor
temperature.
Your new programmable electronic thermostat is
designed to control electric floor heating systems and is
equipped with a microprocessor and proportional integral
adaptive (PIA) temperature control technology for total
comfort.
The TSTAT is also preprogrammed to fit most
homeowners’ lifestyles and settings can be easily
modified if required.
Install the Control Module
Setpoints Definition
Select the Operating Mode
Comfort (default is 28°C)
There are three operating modes:
Press CLK; the hour segment flashes.
Represents the temperature you wish to have when you
are at home (morning and evening).
Manual
Press
to set the hour.
Associated with programs 1 and 3
Press CLK; the minutes segment flashes.
To modify:
Press
Press CLK; the day flashes.
Set the temperature using
and press
until the
icon is displayed on the screen (approx. 3 seconds).
Press
Economy (default is 20°C)
to set the minutes.
to set the day.
Press MODE to exit.
Note: To switch from 12-hour to 24-hour, see “Advanced
Programming” .
Note: After 60 seconds of inactivity, the thermostat will
automatically exit programming mode.
Represents the temperature you wish to have when you
are away at work and during the night.
Associated with programs 2 and 4
To modify:
Set the temperature using
and press
until the
icon is displayed on the screen (approx. 3 seconds).
Maintains a constant temperature.
Press MODE to select
.
Set the temperature using
pre-defined setpoint buttons
or press one of the
.
Automatic
Executes the schedule.
Press MODE to select
.
To bypass the current program for
a 2-hour period, simply define a new setpoint using
The Auto icon flashes to indicate the bypass.
Standby
This mode is used to put the
thermostat in sleep mode when it
is not required (e.g. summer).
Press MODE to select
.
2/3
400-608-000-C
.