Download PPC-CPU852(MS)-512
Transcript
5. Utility Operations 5.5.8 Turning ON/OFF Bit Device Turns on/off the specified bit device. DANGER To perform control (data change) of the PC CPU module during operation, configure an interlock circuit on the user program so that the whole system runs safely at all times. To perform other control (change in the running status (status control)) of the PC CPU module during operation, also configure an interlock circuit on the user program so that the whole system runs safely at all times. Especially, when performing the above control of a remote PC CPU module from an external device, a problem occurring at the PC CPU module due to abnormal data communication may not be addressed immediately. In addition to configuring an interlock circuit on a user program, determine a system method between the external device and PC CPU module in case of abnormal data communication. Point BitDeviceSet (reset) makes it possible to turn ON/OFF devices that can be randomly accessed. If a device that cannot be randomly accessed is turned ON/OFF, a device type error (-3) occurs. For information about the availability of random access support for each device, refer to “Chapter 7 Accessible Range and Devices”. 130 PPC-CPU852(MS)-512