Download VS mini J7 USER`S MANUAL
Transcript
Wiring the Main Circuit L1L2 L3 [Example of 3-phase, 200V class, 1.5kW inverters] • Main circuit input power supply Always connect the power supply line to input terminals R/L1, S/L2, and T/L3 [R/L1, S/L2 for single-phase inverters]. Never connect them to terminal U/T1,V/T2,W/T3, –, +1, or +2. Otherwise the inverter may be damaged. NOTE For single-phase inverters, always use terminals R/L1 and S/L2. Never connect to terminal T/L3. • Grounding (Use ground terminal 24 GOOD Wiring the main circuit terminals Pass the cables through wiring hole and connect. Be sure to mount the cover in its original position. .) Make sure to ground the ground terminal according to the local grounding code. Never ground the VS mini in common with welding machines, motors, or other electrical equipment. When several VS mini units are used side by side, ground each unit as shown in examples. Do not loop the ground wires. GOOD • Inverter output Connect the motor terminals to U/T1, V/T2, W/T3. POOR Connect with a Phillips (plus) screwdriver.